Hoover Condenser Tumble Dryer dxc9tceb-80 E21 –

by / Tuesday, 16 February 2021 / Published in

Hi, pump runs when 230v placed across the terminals, float level switch opens/closes, continuity of cabling from pump and switch to PCB connecter confirmed OKI suspect main board but cant remove knob to examine board, thoughts?Chris

Chris Lynch

Paul answers

I will try and help with your Hoover Condenser Tumble Dryer dxc9tceb-80 problem.

Error E21 usually means excess water left in condenser or condenser pump not working/pumping to the reservoir.
This can be due to wet condenser and/or blocked/faulty pump.
Unplug the appliance and remove the condenser, clean the area and let the condenser dry for a while.
Then plug it back after around 30 minutes. This can also be a problem with the heater element not heating the clothes. Check that the heater is working as intended.
Since there is no pump on these models, if the error persists it might be a fault with the circuit board.

I have listed the diagrams and parts list for this model below for future reference for you and anyone else that needs it.

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

Common Hoover Condenser Tumble Dryer dxc9tceb-80 faults with links to the right repair guide

I have included a lot of videos in the links below on these tumble dryers to assist you in repairing your tumble dryer; I have also included an exploded diagram of your machine with all the parts that you need listed below that just click on the relevant and it will take you to a search result

  1. No heat

This is the most common fault on tumble dryers.

Vented dryers: this can be a fault with the thermostats, heater, or on some occasions, it might be the timer or the relay on the printed circuit board.

Condensor dryers: this might be any of the above but you also have a condenser plate that collects the water and then is either pumped to the collection tray or flows into a tank. Check pump unit and float switches.

Heat pump dryers: these are much more complicated they use a refrigeration prosses to heat the cloths and use the cooling side to condense the water for collection. Check compressor is running, check NTC sensors and check filters, and also that it has the right amount of refrigeration gas (normally only done by an engineer)

  1. Drum not turning

This will stop the dryer from drying. You may have to replace a faulty belt or in other cases, look at the motor, motor capacitor, or the jockey wheels. Again there are relays on printed circuit board types that can go faulty.

  1. Not starting

Whilst, not a common problem, you may have a faulty door switch, starter relay if fitted, or can be start button or PCB.

  1. Noisy Machine

This is usually caused by faulty bearings, jockey wheels or worn felt pads. The motor can get dust build up in the bearings, also the fan blades can distort in shape and make noise rubbing the housing.

  1. Water leaks.

This can be a simple as the water tank (in a condenser tumble dryer) has not been emptied, or not placed back into the housing correctly. The condenser plate can need cleaning. The pump unit might not be working. Or the ducting system can be clogged with fluff etc. See servicing tumble dryer.

  1. Tumble dryer reports a fault code or error code.

Error codes can be on the display or given in certain lights flashing sequences. Tumble dryer fault codes are not universal but may only point you or an engineer in the right direction they are not 100% accurate they are only that for guidance. Your owner’s manual may help you identify the problem and even suggest a fix. In other cases, you’ll need an engineer to trace the fault. Don’t be tempted to ignore a fault code, even if the dryer seems to be functioning normally. Some codes are ‘early warning signs’ and fixing the machine at an early stage could save you time and money in the long run.Contact us with the full model number and detailed description 

If you need any further assistance please feel free to contact me​. all the best Paul​.

photo  
Paul Charmbury
Appliances Engineer
youtube facebook google+ beer

Match your part for Hoover Condenser Tumble Dryer dxc9tceb-80 and use reference number in list below and click on the link to your part

Reference Part Number Description
10 40009430 Timer/select. knob
31b 40011290 Control panel with Sensor
48 40010971 R/H side frame
48a 40010972 L/H side frame
49 40005333 Top rear frame
49g 41041380 Trade mark plate
51 40005221 Work top
60 40009040 Hinge
63 40006231 Door glass
67 40011085 Door with trim
76 40009337 Cabinet-assy
77 40004062 Rear panel
77 40012171 Rear panel
79 40002885 Foot
82 40009192 Door panel
88 40009429 Front panel
131a 92470020 Hose clip
152a 40010529 Light guide support
156 41039164 Capacitor 7 MF
157 40011133 Harness
157 40012503 Harness
161 40005021 Pump
164 91200489 Anti jamming filter radio
171 40008460 Main motor
202 40009120 Drum
202 40011928 Drum
205 40006362 Drum shaft assy
218 03210179 Bearing
229 24721202 Circlip
230 40004306 Bearing clamp
231a 40007401 Pipes holder
271 40005393 Door gasket
280 40009775 Hose clip
292 40001012 Drive belt
292 40012264 Drive belt
318b 49040249 Electronic control PCB - NFC -Programmed
318c 49041739 Electronic NFC pcb - Not programmed
442 40009278 Fan
442a 40009379 Rear fan
443 40011108 Thermostat
444 40012558 Duct fun
445 40012556 Nozzle Cond. Recovery
445a 40012557 Nozzle Cond. Recovery Seal
448 40005010 Heater
448 40012181 Heater
461h 41014595 drying probe seal
491c 91200201 Mains cable x UK
494d 40010528 Light Guide - Digital Display
520 40006928 Door coupler
607 40006220 Pin for hinge
631 40006586 Stopper
643a 41041381 Handle plate - profile
647 40008382 Water condenser
654 40003802 Thermostat gasket
671 03610428 Washer
690 40006246 Rear sealing felt
690a 40004577 Rear cover seal
690c 40010756 Seal motor/water duct
696 40006820 Heater support
697 40003226 Heater support disk
706 40010765 Front ring assembly
706 40012437 Front ring assembly
707 40005584 Filter for carter
727 40004816 Gasket
728 40006251 Gasket
731b 40006360 Flow pipe (Water drain)
731b 40012561 Flow pipe (Water drain)
731c 40009075 Water Delivery Pipe
731d 40012847 Flow pipe clip
734 40007792 Container
734 40012547 Container
738 40004817 Gasket
745 40009339 Kickplate assy
748 03320032 Tube
755 40007362 Cover
755a 40007506 Fan insert
756 23715194 Spring
757 40003315 Gasket
763b 40003319 Water rear duct gasket
763d 40008360 Reservoir top cover
764 40004815 Gasket
766 40011087 Water container assy
766b 40005440 Water container front cover
777 40004157 Heater gasket
797 40004610 Beltightening pulley
799 40001026 Belt tighteningb spring
804 40009167 Hinge fixing upper bracke
819 40009121 Drum scowel
826 40004091 Door hook
835 40004307 Drum support wheels
840 40010626 Float assy
840a 40008358 Floating
840b 41041353 Microswitch
998a 40011292 Eeprom File NFC
999 41045051 Electrical diagram
1004 40005153 Flow restrictor
1017 41022106 NTC probe
1026 40007831 Front felt

full list of spare parts for Hoover Condenser Tumble Dryer dxc9tceb-80