I have recently moved to Australia and since my household goods have arrived the tumble dryer just does not seem to be drying efficiently.

Peter from Melborne

Paul answers

I will try and help with your Hoover Condenser Tumble Dryer HLXC9TE problem.

I hope the weather there is a lot better than in the UK, 

it is important to note as you've been transporting the machine a long distance you want to make sure there are no blockages in the ducting system, I would make sure the all the filters are clean, it is also possible that because the machine was transported a long distance it may have had a knock, this may have caused damage to the heating elements so this would be the first thing I would inspect after you have checked all the filters and ducting. the Heating units are quite fragile and this is why I'm pointing you this direction, I have put some useful videos below to assist you in any repairs that you may have,  also there is an exploded diagram of your machine below.  you might be able to get parts in your country but if not you can always alter them from the UK but they are going to take a while to get to Australia.

i have also put an exploded diagram of the wiring circuit and also a list of all the fault codes normally if you have a heating problem an error code will come up like e21

 

 

 

 

 

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

 

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

Common Hoover Condenser Tumble dryer HLXC9TE  faults with links to the right repair guide

I have included a lot of videos in the links below on these tumble dryers to assist you in repairing your tumble dryer; I have also included an exploded diagram of your machine with all the parts that you need listed below that just click on the relevant and it will take you to a search result

  1. No heat

This is the most common fault on tumble dryers.

Vented dryers: this can be a fault with the thermostats, heater, or on some occasions, it might be the timer or the relay on the printed circuit board.

Condensor dryers: this might be any of the above but you also have a condenser plate that collects the water and then is either pumped to the collection tray or flows into a tank. Check pump unit and float switches.

Heat pump dryers: these are much more complicated they use a refrigeration prosses to heat the cloths and use the cooling side to condense the water for collection. Check compressor is running, check NTC sensors and check filters, and also that it has the right amount of refrigeration gas (normally only done by an engineer)

  1. Drum not turning

This will stop the dryer from drying. You may have to replace a faulty belt or in other cases, look at the motor, motor capacitor, or the jockey wheels. Again there are relays on printed circuit board types that can go faulty.

  1. Not starting

Whilst, not a common problem, you may have a faulty door switch, starter relay if fitted, or can be start button or PCB.

  1. Noisy Machine

This is usually caused by faulty bearings, jockey wheels or worn felt pads. The motor can get dust build up in the bearings, also the fan blades can distort in shape and make noise rubbing the housing.

  1. Water leaks.

This can be a simple as the water tank (in a condenser tumble dryer) has not been emptied, or not placed back into the housing correctly. The condenser plate can need cleaning. The pump unit might not be working. Or the ducting system can be clogged with fluff etc. See servicing tumble dryer.

  1. Tumble dryer reports a fault code or error code.

Error codes can be on the display or given in certain lights flashing sequences. Tumble dryer fault codes are not universal but may only point you or an engineer in the right direction they are not 100% accurate they are only that for guidance. Your owner’s manual may help you identify the problem and even suggest a fix. In other cases, you’ll need an engineer to trace the fault. Don’t be tempted to ignore a fault code, even if the dryer seems to be functioning normally. Some codes are ‘early warning signs’ and fixing the machine at an early stage could save you time and money in the long run.Contact us with the full model number and detailed description 

Hoover Condenser Tumble dryer HLXC9TE Fault codes and errors E03, E05, E07, E08, E10, E12, E13, E14, E15, E19, E21, E22.

Hoover Condenser Tumble dryer HLXC9TE wiring diagram

If you need any further assistance please feel free to contact me​. all the best Paul​.

photo  
Paul Charmbury
Appliances Engineer
youtube facebook google+ beer

Match your part for Hoover Condenser Tumble Dryer HLXC9TE and use reference number in list below and click on the link to your part

full list of spare parts for Hoover Condenser Tumble Dryer HLXC9TE model below

Reference Part Number Description
10 43012818 Timer/select. knob
31b 40015823 Control panel with Sensor
48 40010677 R/H side frame
48a 40010678 L/H side frame
49 40004597 Top rear frame
49g 41041380 Trade mark plate
51 40004601 Work top
60 40009040 Hinge
63 40006231 Door glass
67 40011086 Door with trim
77 40012171 Rear panel
79 40002885 Foot
82 40009428 Door panel
88 40008589 Front panel
93 40011546 MAIN DOOR HOOVER W 2018/T
103 40013534 Drip Cover
131a 92470020 Hose clip
135 40004935 Water valve
136 40004933 Water container valve
152a 40013805 Light guide support
156 41039164 Capacitor 7 MF
157 41046501 Harness
157 40017023 Harness
161 40012912 Pump
164 91200489 Anti jamming filter radio
171 40008460 Main motor
202 40011928 Drum
205 40012471 Drum shaft assy
218 03210179 Bearing
225a 40009928 Gasket
229 24721202 Circlip
230 40004306 Bearing clamp
231a 40007401 Pipes holder
271 40005393 Door gasket
280 40009775 Hose clip
292 40012264 Drive belt
318d 40014816 Electronic BLE pcb - Not programmed
318e 49121033 Electronic control PCB - BLE -Programmed
440a 46004464 Scroll seal
442 40009278 Fan
442a 40009379 Rear fan
443 41037151 Thermostat
444 40012558 Duct fun
445 40012556 Nozzle Cond. Recovery
445a 40012557 Nozzle Cond. Recovery Seal
448 40013366 Heater
461h 41014595 NTC sensor seal
464 03860580 Water offset
491c 41034522 Mains cable x UK
494d 40013745 Light Guide - Digital Display
520 40006928 Door coupler
607 40006220 Pin for hinge
631 40006586 Stopper
643a 41041381 Handle insert
647 40015390 Water condenser
654 40003802 Thermostat gasket
657 41018444 Bracket
671 03610428 Washer
690 40011933 Rear sealing felt
690c 40010756 Seal motor/water duct
691 40011976 Rear cover seal
696 40011929 Heater support
697 40011930 Heater support disk
706 40012494 Front ring assembly
706a 40011352 Duct side filter
707 40005584 Filter for carter
727 40004816 Gasket
728 40006251 Gasket
731b 40012561 Flow pipe (Water drain)
731c 40009075 Water Delivery Pipe
731d 40012847 Flow pipe clip
734 40012545 Container
738 40004817 Gasket
745 40009144 Kickplate assy
748 03320032 Tube
755 40012540 Cover
755a 40007363 Fan insert
757 40003315 Gasket
763b 40003319 Water rear duct gasket
763d 40008360 Reservoir top cover
764 40004815 Gasket
766 40009648 Water container assy
766b 40004928 Water container front cover
777 40011965 Heater gasket
797 40004610 Beltightening pulley
799 40001026 Belt tighteningb spring
804 40009167 Hinge fixing upper bracke
806 40009170 Upper hinge sleeve
807 40009171 Lowen hinge sleeve
819 40011934 Drum scowel
822 40010003 Innerdoor assy
826 40004091 Door hook
835 40004307 Drum support wheels
840 40010626 Float assy
840a 40008358 Floating
840b 41041353 Microswitch
998b 40015827 Eeprom File BLE
999 41045051 Electrical diagram
1004 40005153 Flow restrictor
1017 41022106 NTC probe
1026 40011691 Front felt