Please can you tell me the fault codes on my DYNAMIC NEXT DX C10DE-80
Michelle
Hoover Candy heat pump tumble dryers have numerous error codes. The error code list for your Hoover DX C10DE-80 is listed below
ERROR CODE |
MOST PROBABLE REASON FOR THE ERROR CODE |
E03 |
Tank is full of water and has to be emptied |
E05 |
Front NTC sensor is either short circuit or open circuit. Check front NTC sensor and/or wiring |
E07 |
Alarm, filter occluded, This error can only appear after the end of a cycle. The filter is occluded because of fluff presence, the correct ventilation is not allowed. Clean the filter |
E08 |
Thermo fuse intervention. Replace the thermo fuse and check that ventilation circuit is clean, check the wiring |
E10 |
Missing communication between "Cuore" Electric Module and Display Electric Module and/or Wiring |
E11 |
In the rear part of condenser the temperature is too high. Check that all ventilation ducts are clean, check that ventilation system is working well. Check the condenser, the moto the fan could be broke/blocked. |
E12 |
Pressure switch doesn’t work. Check the pressure switch and/or wiring. Check that the air trap is clean |
E13 |
Compressor NTC Probe is either Short Circuit or Open Circuit. Check the compressor NTC probe and/or wiring |
E14 |
Rear NTC Probe is either Short Circuit or Open Circuit. Check the rear NTC probe and/or wiring |
E15 |
Main board not programmed. Program the main board |
E19 |
It is not possible to use NFC tag for any actions until the next POWER ON/OFF. (switch off and switch on) |
E21 |
Heater control relay on the “cuore” electric module is not working. High temperature has been reached - Thermo Fuse worked. Check the Thermo Fuse, and the wiring. Check both the ventilation circuit and ventilation ducts are clean and duct is not obstructed. Replace the “cuore” electric module only in the case that the heater command relay is faulty |
E22 |
Compressor control relay on the “cuore” electric module is not working. Check the compressor and compressor wiring/connections. Replace the “cuore” electric module only in the case that the compressor command relay is faulty. |
Hi,
The start button on my tumble dryer is unresponsive. the only way to start the cycle is via the app, which is quite inconvenient. Please advise.
Thanks
dryer is just beeping and not functioning
can you advise what this may be due to please
Thanks
David