Heat pump tumble dryer
Test mode on Aeg, Electrolux, John Lewis, zanussi heat pump Tumble dryers
It is very difficult sometimes to diagnose the problems with these heat pump tumble dryers.
I have included a video to show you the test mode sequence and also a PDF below which I managed to obtain.
but whenever you need parts for these dryers you will need to quote your model number and also the PCN number before we can do that you to the correct part
if you are still having trouble please contact us using your full model number including the product number for help from Paul
Finding your problem with a heat pump tumble dryer can be difficult on occasions as these tumble dryers dry the clothes using Refrigeration process.
These are some of the common error codes or faults
All dryers will show the alarm code on the time to end display.
The alarm will be shown as EX Y e.g. E51E = ErrorX = alarm family Y = alarm number
Alarm
description:
E21
Tank drain pump triac failure.
E22
Tank drain pump triac sensing failure.
E31
Conductimetric sensing oscillation frequency too high
E32
Conductimetricsensing oscillation frequency.
too low
E51
Motor triac failure.
E52
Motor thermal cut off.
E53
Motor triac sensing failure.
E54
Motor jammed
E61
Heating timeout
E62
Compressor relay failure
E63
Compressor automatic thermostat
E64
Compressor sensing failure
E65
Main Fan relay failure
E66
Main fan automatic thermostat
E67
Main fan sensing failure
E71
Drying NTC1 failure
E72
Drying NTC2 failure
E82
Wrong selector reset position detection
E93
Machine configuration error
E94
Cycle Configuration error failure
E95
Communication error between microprocessor
and external EEPROM
E97
SCF –CTF mismatch error
EB1
Power supply frequency out of limits
EB2
Power supply voltage too high
EB3
Power supply voltage too low
Safety first! Unplug the machine from the electrical supply and make sure the machine has been idle long enough so that the heater has cooled down.
Once a year vacuum the inside taking special care on the wiring, it is very important to clean all the vent tubes on a regular basis. Clean the heat exchanger (condenser dryers only)
We hope this tutorial helped you get your tumble dryer working again!
This is Full workshop manual on these type dryers
-
Replacing White Knight Tumble Dryer Belt and other makes listed
-
White knight tumble dryer vibrating noise, not drying clothes quickly
-
Tumble dryer not turning common faults, plus motor change on a White Knight
-
Tumble dryer not heating Check element & Thermostats White Knight
-
Noisy Tumble Dryer Replace back bearing on White Knight & some others 421309205591
-
White knight how to replace vent hose & service tumble dryer
-
White Knight Crosslee Compact Tumble Dryer not heating or tripping electric supply
-
Tumble dryer is not turning? How to find the fault and replace motor capacitor
-
How to test a tumble dryer that is not heating and change a thermostat that is faulty
16 Responses to “Heat pump tumble dryer”

Can you send me the pdf for personal use? Thanks
Hello
I have the AEG T865901H3 and the error code is EH0 !!! HELP!!!!
THANKS
hi can you please tell me where the dry sensor is for the AEG T56830 Lavatherm as it is not drying properly .have cleaned all the filters and the matrix and reset the sensor to the top setting buy using the Adjust ’level of dryness’
detection:
In the programming options .many thanks Dave
Olá!
Como solucionar o problema ERROR EH0?
Olá!
Minha maquina está apresentando um mensagem de erro EH0 / EHO.
Modelo: L 73480 FL
Consegue ma ajudar.
Rodolfo.
São Jose dos Campos – SP Brazil.
Zaap 55 12 997921517. Help Help Help.
Hello Paul!
I will start by saying, thanks a lot for the help and the instructions you give.
I have a very similar tumbler like the one you stripped down and showed us how to get into service mode. Mine Is a six years old Husqvarna QW9281 no 916 097 136 00. And my problem is it won’t dry our clothes. It seems that the machine don’t heat any more. It stops after an half hour and it is wet and just a hint of heat. I tested it liked you showed and got this error code E32. Have you any advice?
Cheers
Fredrik Björkander
Sweden 🇸🇪
Would you know by any chance where i would find TUMBLE DRYER OVERHEAT PROTECTION THERMOSTAT in model AEG T86580IH? I need to try to reset it. thank you
Hi Paul and good afternoon to you,
I have a JLTDH 16 made by John Lewis.
I don’t get any water back to the water dispenser, hence the clothes aren’t drying correctly .
I have cleaned out all the filters and i have gone into the test mode and on,
C2 it comes up with 111
C 8 COMES UP WITH E 32
C 9 comes up 111
C 10 comes up with E 32
I se on your error codes that E 32 is Conductimetricsensing oscillation frequency.
too low.
To a layman any pointers to what can be wrong, if so is it expensive for the part the tumble is 6 years old,
Thankyou so much for tutorial on your web page i found it so interesting,
Best Regards Bill
Hi again Paul,
i just tried out my tumble dryer again and it finished with error code of E 60, with no water coming back. i took the top off previously and tried the jug of water as shown on you tutorial and the pump was returning water ok.
Best Regards Bill
Hi there i’m looking for the location of the NTC sensor for the AEG T885951S condenser dryer
i also have a code coming up saying ( ren,) i can’t find any info on this code IT also said E73 ccan you help me get back to regular settings
Help please my Gorenje heat pump dryer model number d76sy2b doesnt want to start. It just keeps beeping 3 times when i try to start any cycle. I have checked all the obvious including the door switch. The dryer is onlyv4 years old. What could the fault be
Hello, I have a Bosch WTW85490GB Heat Pump Tumble Dryer and the Dryer is not collecting water in the tray. Do you have the equivalent Diagnostic sequences which you showed on the AEG/John Lewis model for the Bosch machines? That would be exceedingly helpful and would in return like to buy you a Beer! Thanks Howard
Hi. I have a Candy model CS H8A2LE-80/ heat pump dryer. I bought it new and it came with a one year warranty. Shortly after the year elapsed the dryer appeared to malfunction. There is a tank attached to the door that collects the moisture/water from the clothes as they are dryed. What happened is the water was no longer being sent to the tank. My first thought was that the line from where the water accumulates to the tank was clogged. I removed it and checked it. No clog whatsoever. After further research I figured the pump that sends the water to the tank had died. I ordered a replacement and installed it. Made no difference. What I’ve been doing in the meantime is still using the dryer. If I take the clothes from the washer after a 1500 rpm spin cycle and hang them on a line for a few hours, most of the dampness seems to dry. I then put the clothes in the dryer and run it like I did before. The dryer gets warm and does eventually dry the clothes, but still no water collects in the tank. It does, however seem to me the room where this is taking place is becoming quite humid. Well, after all, the moisture has to go somewhere. So…….it appears I have a dryer that works at removing the dampness from the clothes but, instead of collecting it in the ‘staging’ area to send it to the storage tank in the door, it just gets sent through the exhaust vent into the room. Could you please steer me in the right direction as to how I can sort this? Thank you in advance! 🙂
Hi Paul
I have an AEG LAVATHERM 8DEC946R Tumble Dryer and am experiencing a small amount of water appearing under the condenser which can be cleaned up with a tissue. There is no fault code appearing but as this has not happened in the four years, we have owned the dryer I am wondering if I should call out an engineer to repair the dryer if needed while it’s still under warranty. The condenser has been regularly cleaned and this has only become apparent recently.
Regards
Tony
Hello Paul, my Candy Grand O’Vita GVHD913A2 keeps error coding E01!
Can you help diagnose which apart is faulty please?
I have a Samsung “heat pump” tumble drier. Out of warranty but only 28 months old.
I have had two engineers to look at it. Both diagnosed different parts not working??
Eventually, the last engineer * having put in a new water pump,which made no difference,diagnosed that it was the heat pump. His attitude was the machine was “caput”.
There was no warning on the panel.
The clothes were not drying and the condenser was not filling up.
Model DV80M5013QW/EU.
Do these engineers know how to repair these “heat pump” machines.
Please Help. I need to know if this is the right diagnoses and can it be repaired.
Thank you