Tumble Dryer fault code errors Aeg, Electrolux, Zanussi Etc
How to use the diagnostic mode for fault code errors
These error codes are for ENVo6 Cuirct boards tumble dryer  Electrolux, AEG, Arthur Martin, Elektro Helios, Eureka, Faure, Frigidaire, Gibson Appliance, Husqvarna, Kelvinator, Marijnen, Parkinson Cowan, Progress, Simpson, Tornado, Tricity Bendix, Volta, Westinghouse, Zanker, Zanussi, Zoppas,
If these fault codes apply to your Tumble dryer it should have a fascia panel on it like one of those shown below, there are four known variants covering quite literally hundreds of different models sold in the UK and across the EU.
Error Codes for Env06 Tumble dryer boards:
Â
E00
No alarm.
E21Â
Canister fill pump triac faulty.
Possible fault Wiring faulty; Electronic board faulty. Cycle interrupted. OFF
E22
Triac "sensing" circuit for the canister fill pump faulty
Possible fault Electronic board faulty. Cycle interrupted. Machine Status/Action OFF
E31
Conductimetric sensor signal frequency too high.
Possible fault Electronic board faulty.Machine Status/Action Alarm activated only during diagnostics.
E32
Conductimetric sensor signal frequency too low.
Possible fault  Wiring faulty; Brushes worn/faulty; Electronic
board faulty. Machine Status/Action  Cycle interrupted.
E33
It is displayed in the last alarm, if position 8 is NOTÂ OK.
Possible fault Wiring faulty; Brushes worn/faulty; Electronic
board faulty.  Machine Status/Action Alarm activated only during diagnostics.
E45
Door closure sensor.
Possible fault Door interlock faulty; Wiring faulty; Electronic board faulty. Machine Status/Action Cycle interrupted.
E51
Motor power triac short-circuited.
Possible fault Motor faulty; Wiring faulty; Electronic board faulty. Machine Status/Action Cycle interrupted.
E52
Intervention of motor overheating safety cut-out.
Possible fault Motor faulty; Intervention of motor overheating cutout; Wiring faulty; Electronic board faulty.
Machine Status/Action Power to the heater unit and reversal of the direction of rotation are interrupted. If the problem does not re-occur, the alarm is memorized and the cycle continues. If the fault persists after several attempts to supply power (about 35 min.), alarm E51 is generated.
E53
Motor triac "sensing" circuit faulty.
Possible fault Electronic board faulty. Machine Status/Action Cycle interrupted.
E54
Motor in-operational.
Possible fault Excessive wash load; Voltage too low; Motor/transmission system inoperative.
Machine Status/Action Cycle paused after several attempts at powering the motor. Start
E61
Insufficient heating (maximum time exceeded).
Possible fault  Heater unit faulty; Wiring faulty; NTC sensor incorrectly calibrated/out of position; Electronic board faulty.
Machine Status/Action Cycle paused.
E62
Power relay to heater unit faulty.
Possible fault Heater unit faulty; Wiring faulty; Electronic board faulty.
Machine Status/Action Forced cooling cycle.
E63
Intervention of auto-reset thermostat on the heater unit.
Possible fault Thermostat faulty (replace heater unit); Heater unit faulty; Wiring faulty; Electronic board faulty.
Machine Status/Action Disconnects the power supply to the heater unit. If the problem does not re-occur, the alarm is memorized and the cycle continues. If, after several attempts to restore power, the fault persists, alarm E62 is generated.
E64
Heater thermostat.
Possible fault Heater thermostat faulty: Wiring faulty; Electronic board faulty.
E65
Fan motor triac faulty.
Possible fault Fan motor wiring not connected; Motor faulty; Triac interrupted.
E66
Fan motor thermal protection.
Possible fault Fan motor wiring not connected; Motor faulty; Triac interrupted.
E67
Triac control faulty.
Possible fault Fan motor wiring not connected; CRM board faulty.
E71
NTC1 sensor faulty.
Possible fault NTC1 sensor faulty; Wiring faulty; Electronic board faulty. Machine Status/Action Forced cooling cycle.
E72
NTC2 sensor faulty.
Possible fault NTC2 sensor faulty; Wiring faulty; Electronic board faulty.
E82
Selector in OFF position faulty.
Possible fault Board wiring; board faulty.
E83
Selector positions wrong.
Possible fault Board wiring; board faulty.
E93
Error in the configuration of the appliance.
Possible fault EEPROM configuration incorrect. Electronic board faulty. Cycle interrupted. OFF
E94
Error in the configuration of the drying cycle. EEPROM configuration incorrect.
Possible fault Electronic board faulty. Machine Status/Action Cycle interrupted.
E97
Incongruence between selector and cycles.
Possible fault Configuration error. Machine Status/Action Cycle interrupted.
EA1
CRM board communication faulty.
Possible fault Board wiring; CRM board faulty.
EA2
CRM board protocol inconsistent.
Possible fault Software wrong; CRM board faulty.
EA3
Board selector faulty.
Possible fault Electronic board faulty.
EA4
Selector protocol wrong. Electronic board faulty.
EB1
Power frequency to appliance out of limits.
Possible fault Problems with the power supply (incorrect/interference). Electronic board faulty.
Machine Status/Action  Cycle interrupted. If a stable power supply is restored before the time-out has elapsed, the cycle resumes.
EB2
Power voltage too high.
Possible fault Problems with the power supply (incorrect/interference). Electronic board faulty.
Machine Status/Action Cycle interrupted
EB3
Power voltage too low.
Possible fault Problems with the power supply (incorrect/interference). Electronic board faulty.
Machine Status/Action Cycle interrupted. If a stable power supply is restored before the time-out has elapsed, the cycle resumes.
EC1
Voltage incongruence between boards.
Possible fault Problems with the power supply (incorrect/interference). CRM board faulty.
EC2
Frequency incongruence between boards.
Possible fault Problems with the power supply (incorrect/interference). CRM board faulty.
EC3
CRM resistance out of time (only in diagnostic mode).
Possible fault CRM group not connected; CRM group faulty.
EC4
Steam generator (CRM) heater relay.
Possible fault CRM group not connected; relay on board faulty.
EC5
CRM thermostat faulty.
Possible fault CRM group not connected; CRM group faulty.
EC6
CRM piloting faulty.
Possible fault CRM board faulty.
EC7
CRM pump triac.
Possible fault Pump wiring not connected; pump faulty; Triac faulty.
EC8
CRM pump diode.
Possible fault Diode on wiring short-circuited.
EC9
CRM pump piloting faulty. CRM board faulty.
ECA
Water tank empty.
Possible fault Tank level sensor wiring; tank level sensor faulty; water tube obstructed.
Hi…I have an Electrolux EDI 97170W condenser dryer. After 80mins of use, error E54 error code will appear. I also noticed the tumbling action only goes clockwise and no longer go clockwise like it used to.
Could you help me understand what could be the problem? Does it involve changing the main circuit board?
hi there… we have a zanussi zdc68560w and have a err code 50 showing on the panel. have you any idea what err 50 could mean.
many thanks in anticipation.
hi
i have an electrolux insight tumble dryer and it keeps giving me an E80 error code. What does this mean please? thanks
Hey, how did you fix it?
please contact me on bisc8@hotmail .com if you see this
when you have a question please use contact us page for 24 hour response https://how-to-repair.com/help/contact-us/
Get Appliance help from Paul, Email him
Appliances Engineer
Hello, i have a AEG T65280AC dryer, PNC: 916 096 676 01, with TC3 facial panel.
The dryer is not heating. First i have checked the heater. The heater is ok. I replaced also the NTC.
I got the error codes E71/E72, but i found only one NTC, placed in the front fan housing.
Can you help me with ethe diagnostic programm and how to solve this problem.
Thank you.
Hi!
Thanks for your guides and your instructional videos!
We have at home an Electrolux EDC77550w that stopped in the middle of a drying and won’t turn ON again. I am afraid I cannot access the diagnostics if the panel (similar to the TC4 on this page) doesn’t turn ON. I got a copy of the repair manual, but do not now where to start the diagnostics. Do you have some suggestion?
Thanks in advance!
I would visually inspect the circuit board for any blown chips as I show you in one of our videos
Appliances Engineer
For washing machine time manager 11 kg, What does it mean, i’ve an error code dr? Kindly advise. Thank you
Hello, i have a AEG T88840 dryer, PNC: 916 096 349 0 0.
I got the error code EC5.
Can you help me how to solve this problem.
Thank you.
EC5
CRM thermostat faulty.
Possible fault CRM group not connected; CRM group faulty.
please see this https://how-to-repair.com/help/tumble-dryer-fault-code-errors-aeg-electrolux-zanussi-etc/
Appliances Engineer
Code E00, ??
when you have a question please use contact us page for 24 hour response https://how-to-repair.com/help/contact-us/
Get Appliance help from Paul, Email him
Appliances Engineer
Hello, i have a AEG T75280AC dryer, Type TC09H6MHW, Product No. : 916 096 751 02, with TC2 facial panel.
I got the error codes E60 which is not on youe list..
Can you help me with the diagnostic programm and how to solve this problem.
Thank you.
when you have a question please use contact us page for 24 hour response https://how-to-repair.com/help/contact-us/
Get Appliance help from Paul, Email him
Appliances Engineer
Great helpful video, I have a Zanussi ZDC68560W that was working just fine but has now packed up so I did your test. on the first test I moved the control to the right the lights all flashed and C7 was on the LED it seems to be ok, I then moved it one more right and a C5 appeared and the a 111 appeared in the readout, then a ESE appeared I moved it one more and checked the pump a C13 was shown on the LED the water pump was working fine checked. Then C9 then a ESE, moved again C8 then a flashing 14 the ESE, now I get a E62 fault on each turn
when you have a question please use contact us page for 24 hour response https://how-to-repair.com/help/contact-us/
Get Appliance help from Paul, Email him
Appliances Engineer
Hi,
I have aeg 59840 and it gives error e32 any ideas. It works but the drying pump does not start.
Regards
Jari
when you have a question please use contact us page for 24 hour response https://how-to-repair.com/help/contact-us/
Get Appliance help from Paul, Email him
Appliances Engineer
I have a zanussi zdc 47200w. Product no 916 094 547 type p542553. Stops after a few mins and flashes red with beeping. Done a test and the start button flashes 7 times. Any help would be appreciated
when you have a question please use our site for 24 hour response https://how-to-repair.com/help/contact-us/
Appliances Engineer
I have a Zanussi ZD4700W condensor drier
The other day it stopped mid cycle.
All the LED lights went out and now there are no lights
I have tested mains continuity all the way to the input plug at the PCB. The small transformer has small resistances showing so it is not blown.
Any ideas please? Seems like PCB so I bought another (used!) with correct serial numbers. Now it works but the LED light says ‘cooling’ and no other lights work.
Is it time for a new machine?
Thanks
when you have a question please use our contact us page for 24 hour response https://how-to-repair.com/help/contact-us/
Appliances Engineer
Hi,
I have an electrolux ED78550W tumbler drier. No error code. The program is starting, the display is working, time is shown, relay switches (audible) but nothing else happens. No rotating, no pumping, no heating. What can it be?
Hi,
I’ve got a problem with my AEG Lavatherm T57820.
Error message “Err” flashes 3 times when I either press start/stop or the door button. Does that on any chosen program.
I did change the door lock sensor but the issue persists.
It is bought 2005 and since then I have changed the following items. Belt, heating element and circuit board. all in last 3 years. Some said I’m crazy but the parts weren’t that expensive.
kind regards,
G
Hi,
i have an ELECTROLUX EDH3686GDE Tumble dryer with TC3 facial panel and when i press the start button , on the screen appears “err” code and the machine doesn’t work.
can you please help me.
regards
Diamantis
hi i have a aeg t75280ac with era code e70 what dose it mean thanks
I have an AEG LAVATHERM T65270AC Tumble dryer which has stopped heating up.
How do I get into diagnostics mode? It has a TC3 Facia panel.
I have had the heater unit off and found all of the heater element has continuity. The thermostat has continuity but the dome shaped sensor with two wires (Iâm guessing might be another thermal switch or fuse) has no continuity or resistance value. Is that normal?
I have also found 240 volts on the heater plug at all three heater contacts when the machine is turned on. Yet the thing does not heat up?
If you can help on this matter I would greatly appreciate it.
Kind regards
Keith
I have a john lewis JLTDH21 the machine is blowing cold air only and the only error code I get is e45 which is to do with the door can you help me
Hello, i have a AEG dryer, , Product No. : 91609764200, with TC2 facial panel.
I got the error codes E31 , Can you help me with the diagnostic programm and how to solve this problem,
Thank you.