Tumble Dryer fault code errors Aeg, Electrolux, Zanussi Etc

by / Saturday, 13 December 2014 / Published in Tumble Dryers

How to use the diagnostic mode for fault code errors

These error codes are for ENVo6 Cuirct boards tumble dryer  Electrolux, AEG, Arthur Martin, Elektro Helios, Eureka, Faure, Frigidaire, Gibson Appliance, Husqvarna, Kelvinator, Marijnen, Parkinson Cowan, Progress, Simpson, Tornado, Tricity Bendix, Volta, Westinghouse, Zanker, Zanussi, Zoppas,




Tumble Dryer facial panel types

 

 

 

 

If these fault codes apply to your Tumble dryer it should have a fascia panel on it like one of those shown below, there are four known variants covering quite literally hundreds of different models sold in the UK and across the EU.

Error Codes for Env06 Tumble dryer boards:

 

E00

No alarm.

E21 

Canister fill pump triac faulty.

Possible fault Wiring faulty; Electronic board faulty. Cycle interrupted. OFF

E22

Triac "sensing" circuit for the canister fill pump faulty

Possible fault Electronic board faulty. Cycle interrupted. Machine Status/Action OFF

E31

Conductimetric sensor signal frequency too high.

Possible fault Electronic board faulty.Machine Status/Action Alarm activated only during diagnostics.

E32

Conductimetric sensor signal frequency too low.

Possible fault  Wiring faulty; Brushes worn/faulty; Electronic

board faulty. Machine Status/Action  Cycle interrupted.

E33

It is displayed in the last alarm, if position 8 is NOT OK.

Possible fault Wiring faulty; Brushes worn/faulty; Electronic

board faulty.  Machine Status/Action Alarm activated only during diagnostics.

E45

Door closure sensor.

Possible fault Door interlock faulty; Wiring faulty; Electronic board faulty. Machine Status/Action Cycle interrupted.

E51

Motor power triac short-circuited.

Possible fault Motor faulty; Wiring faulty; Electronic board faulty. Machine Status/Action Cycle interrupted.

E52

Intervention of motor overheating safety cut-out.

Possible fault Motor faulty; Intervention of motor overheating cutout; Wiring faulty; Electronic board faulty.

Machine Status/Action Power to the heater unit and reversal of the direction of rotation are interrupted. If the problem does not re-occur, the alarm is memorized and the cycle continues. If the fault persists after several attempts to supply power (about 35 min.), alarm E51 is generated.

E53

Motor triac "sensing" circuit faulty.

Possible fault Electronic board faulty. Machine Status/Action Cycle interrupted.

E54

Motor in-operational.

Possible fault Excessive wash load; Voltage too low; Motor/transmission system inoperative.

Machine Status/Action Cycle paused after several attempts at powering the motor. Start

E61

Insufficient heating (maximum time exceeded).

Possible fault  Heater unit faulty; Wiring faulty; NTC sensor incorrectly calibrated/out of position; Electronic board faulty.

Machine Status/Action Cycle paused.

E62

Power relay to heater unit faulty.

Possible fault Heater unit faulty; Wiring faulty; Electronic board faulty.

Machine Status/Action Forced cooling cycle.

E63

Intervention of auto-reset thermostat on the heater unit.

Possible fault Thermostat faulty (replace heater unit); Heater unit faulty; Wiring faulty; Electronic board faulty.

Machine Status/Action Disconnects the power supply to the heater unit. If the problem does not re-occur, the alarm is memorized and the cycle continues. If, after several attempts to restore power, the fault persists, alarm E62 is generated.

E64

Heater thermostat.

Possible fault Heater thermostat faulty: Wiring faulty; Electronic board faulty.

E65

Fan motor triac faulty.

Possible fault Fan motor wiring not connected; Motor faulty; Triac interrupted.

E66

Fan motor thermal protection.

Possible fault Fan motor wiring not connected; Motor faulty; Triac interrupted.

E67

Triac control faulty.

Possible fault Fan motor wiring not connected; CRM board faulty.

E71

NTC1 sensor faulty.

Possible fault NTC1 sensor faulty; Wiring faulty; Electronic board faulty. Machine Status/Action Forced cooling cycle.

E72

NTC2 sensor faulty.

Possible fault NTC2 sensor faulty; Wiring faulty; Electronic board faulty.

E82

Selector in OFF position faulty.

Possible fault Board wiring; board faulty.

E83

Selector positions wrong.

Possible fault Board wiring; board faulty.

E93

Error in the configuration of the appliance.

Possible fault EEPROM configuration incorrect. Electronic board faulty. Cycle interrupted. OFF

E94

Error in the configuration of the drying cycle. EEPROM configuration incorrect.

Possible fault Electronic board faulty. Machine Status/Action Cycle interrupted.

E97

Incongruence between selector and cycles.

Possible fault Configuration error. Machine Status/Action Cycle interrupted.

EA1

CRM board communication faulty.

Possible fault  Board wiring; CRM board faulty.

EA2

CRM board protocol inconsistent.

Possible fault Software wrong; CRM board faulty.

EA3

Board selector faulty.

Possible fault Electronic board faulty.

EA4

Selector protocol wrong. Electronic board faulty.

EB1

Power frequency to appliance out of limits.

Possible fault Problems with the power supply (incorrect/interference). Electronic board faulty.

Machine Status/Action  Cycle interrupted. If a stable power supply is restored before the time-out has elapsed, the cycle resumes.

EB2

Power voltage too high.

Possible fault Problems with the power supply (incorrect/interference). Electronic board faulty.

Machine Status/Action Cycle interrupted

EB3

Power voltage too low.

Possible fault Problems with the power supply (incorrect/interference). Electronic board faulty.

Machine Status/Action Cycle interrupted. If a stable power supply is restored before the time-out has elapsed, the cycle resumes.

EC1

Voltage incongruence between boards.

Possible fault Problems with the power supply (incorrect/interference). CRM board faulty.

EC2

Frequency incongruence between boards.

Possible fault Problems with the power supply (incorrect/interference). CRM board faulty.

EC3

CRM resistance out of time (only in diagnostic mode).

Possible fault CRM group not connected; CRM group faulty.

EC4

Steam generator (CRM) heater relay.

Possible fault CRM group not connected; relay on board faulty.

EC5

CRM thermostat faulty.

Possible fault CRM group not connected; CRM group faulty.

EC6

CRM piloting faulty.

Possible fault CRM board faulty.

EC7

CRM pump triac.

Possible fault Pump wiring not connected; pump faulty; Triac faulty.

EC8

CRM pump diode.

Possible fault Diode on wiring short-circuited.

EC9

CRM pump piloting faulty. CRM board faulty.

ECA

Water tank empty.

Possible fault Tank level sensor wiring; tank level sensor faulty; water tube obstructed.

TOP