Hi Do you have the diagnotic sequence for Bosch Heat Pump Tumble Dryers? Would be happy to buy you that pint if you can help. Cheers Howard

Howard Marshall

Paul answers

I will try and help with your Bosch Condenser Tumble Dryer WTW85490GB problem.

I'm sorry I do not have the test sequence on this Bosch tumble dryer but I have found a couple of useful videos for you they are in German,  but they may be useful. I have also added an exploded diagram below showing you all the components on this tumble dryer I'm the part numbers next to them

 

 

 

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

These are in german and not made by myself

Common Bosch Condenser Tumble Dryer WTW85490GB faults with links to the right repair guide

I have included a lot of videos in the links below on these tumble dryers to assist you in repairing your tumble dryer; I have also included an exploded diagram of your machine with all the parts that you need listed below that just click on the relevant and it will take you to a search result

  1. No heat

This is the most common fault on tumble dryers.

Vented dryers: this can be a fault with the thermostats, heater, or on some occasions, it might be the timer or the relay on the printed circuit board.

Condensor dryers: this might be any of the above but you also have a condenser plate that collects the water and then is either pumped to the collection tray or flows into a tank. Check pump unit and float switches.

Heat pump dryers: these are much more complicated they use a refrigeration prosses to heat the cloths and use the cooling side to condense the water for collection. Check compressor is running, check NTC sensors and check filters, and also that it has the right amount of refrigeration gas (normally only done by an engineer)

  1. Drum not turning

This will stop the dryer from drying. You may have to replace a faulty belt or in other cases, look at the motor, motor capacitor, or the jockey wheels. Again there are relays on printed circuit board types that can go faulty.

  1. Not starting

Whilst, not a common problem, you may have a faulty door switch, starter relay if fitted, or can be start button or PCB.

  1. Noisy Machine

This is usually caused by faulty bearings, jockey wheels or worn felt pads. The motor can get dust build up in the bearings, also the fan blades can distort in shape and make noise rubbing the housing.

  1. Water leaks.

This can be a simple as the water tank (in a condenser tumble dryer) has not been emptied, or not placed back into the housing correctly. The condenser plate can need cleaning. The pump unit might not be working. Or the ducting system can be clogged with fluff etc. See servicing tumble dryer.

  1. Tumble dryer reports a fault code or error code.

Error codes can be on the display or given in certain lights flashing sequences. Tumble dryer fault codes are not universal but may only point you or an engineer in the right direction they are not 100% accurate they are only that for guidance. Your owner’s manual may help you identify the problem and even suggest a fix. In other cases, you’ll need an engineer to trace the fault. Don’t be tempted to ignore a fault code, even if the dryer seems to be functioning normally. Some codes are ‘early warning signs’ and fixing the machine at an early stage could save you time and money in the long run.Contact us with the full model number and detailed description 

If you need any further assistance please feel free to contact me​. all the best Paul​.

photo  
Paul Charmbury
Appliances Engineer
youtube facebook google+ beer

Match your part for Bosch Condenser Tumble Dryer WTW85490GB and use reference number in list below and click on the link to your part

Reference Part Number Description
0101 12005911 Tray handle-dispenser
0102 00636984 Knob-programme
0103 00632362 Coupling
0104 12009779 Display
0106 00644995 Power cord
0107 11005689 Panel-facia
0108 00634217 Power module programmed
0108 12027050 Power module not programmed
0110 00634216 Operating module programmed
0110 11024433 Operating module not programmed
0112 00707162 Duct
0199 00635382 Insulating part
0199 17000183 Corner nozzle
8001 17000183 Corner nozzle
8006 00576101 Stacking kit
8050 10008816 Adapter

Reference Part Number Description
0201 00711862 Panel side
0202 00711862 Panel side
0203 00687302 Front panel
0204 00771644 Hood
0205 00632489 Sealing
0207 00613752 Seal
0209 00717062 Case-rear part
0210 00623802 Cover
0211 00617720 Lamp
0212 00707166 Duct
0214 00623797 Latch
0217 11018215 Electrode
0219 00710927 Bearing shield
0220 00623850 Switch-door
0222 00656034 Sealing
0223 00656033 Filter-fluff
0227 10001811 Cover
0230 00771777 Worktop
0231 00613598 Wheel
0232 00707056 Cover
0237 11010142 Front rail
8001 17000183 Corner nozzle
8006 00576101 Stacking kit
8050 10008816 Adapter

Reference Part Number Description
0303 11012059 Window
0306 00746644 Glass cover
0307 00747799 Ring
8001 17000183 Corner nozzle
8006 00576101 Stacking kit
8050 10008816 Adapter

Reference Part Number Description
0401 00497211 Drive coupling
0402 00650499 Belt-drive
0403 00618931 Bearing
0404 00652500 Seal set - drum support
0405 00649045 Sealing
0407 00249014 Drum
0410 00652502 Taper
8001 17000183 Corner nozzle
8006 00576101 Stacking kit
8050 10008816 Adapter

Reference Part Number Description
0501 00611942 Foot
0502 00145443 Motor
0503 00619115 Spring
0504 00632045 Roller-tension
0506 00651456 Fan
0507 00752112 Fan drum
0508 00622991 Capacitor-metal paper
0510 00613787 Sealing
0512 00146123 Pump
0513 00631076 Electro magnet
0514 00707095 Housing
0515 00619697 Filter
0516 00707089 Container-condensed water
0517 12003936 Hose-recirculation
0519 00646967 Sealing
0521 00630596 Capacitor-metal paper
0522 00754653 Diffuser
0523 00629623 Hose clamp
0524 00613959 Sealing
0525 00625431 Hose-fill
0527 00170961 Sensor-NTC
0528 00613776 Spring
0529 00657918 Hose-recirculation
0530 00657920 Outlet set
0534 00752294 Support
0536 00552829 Part not included in this appliance
0537 00552829 Part not included in this appliance
0538 00145545 Compressor
0539 00656128 Cover
0540 00754118 Repair-set
0550 12013826 Outlet hose
0551 00655300 Holder
0552 00625434 Connection
0554 12013827 Hose-fill
0555 00629040 Locking cap
8001 17000183 Corner nozzle
8006 00576101 Stacking kit
8050 10008816 Adapter

Reference Part Number Description
0601 00629382 Cable harness
0602 00629532 Cable harness
0603 00631141 Cable harness
0604 00629384 Cable harness
0605 00629527 Cable harness
0606 00629386 Cable harness
0607 00629528 Cable harness
0608 00634062 Cable harness
0609 00629529 Cable harness
0610 00629390 Cable harness
0611 00629530 Cable harness
0612 00629531 Cable harness
8001 17000183 Corner nozzle
8006 00576101 Stacking kit
8050 10008816 Adapter

full list of spare parts for Bosch Condenser Tumble Dryer WTW85490GB

Our How-to-repair stores

Current page 1 Total pages 0
  • Bosch NEFF Siemens Washing Machine Power Cord Lead 00644995 With Plug

    Category: Recycle Appliances

    £9.85
  • Bosch NEFF Siemens Condenser Tumble Dryer Foot 00611942

    Category: Recycle Appliances

    £4.45
  • Bosch NEFF Siemens Tumble Dryer Agitator, Drum Paddle, Drive Coupling 00497211

    Category: Recycle Appliances

    £5.45
  • Bosch NEFF Siemens Tumble Dryer Drum Roller Wheel 00613598

    Category: Recycle Appliances

    £16.35
  • Bosch NEFF Siemens Tumble Dryer Rear Bearing 00618931

    Category: Recycle Appliances

    £12.65

One Response to “Bosch Condenser Tumble Dryer WTW85490GB Not collecting water”

  1. Adam says : Reply

    Hi we have a very 6 WTW85490GB/01 FD95/2
    The door latch has broken do I need to buy a new don’t. I have removed the out trim and glass cover but I can not remove the rest
    Many thanks

24h technical help answers

Questions on faults in the comments will not be answered. Please use the contact us form instead.

TOP