Every time i switch start button on it trips out the electric rcd .

anthony haywood

Paul answers

I will try and help with Beko Condenser Tumble Dryer DC7112W problem.

This is normally one of two problems which are quite common as this is a condenser tumble dryer sometimes when the filters and ducting gets restricted in airflow in other words the machine has not been maintained very well a large amount of moisture can gather around the heating element this would cause the RCD in your electrical board to trip,  the second most common problem is you have a faulty motor this is straightforward it will just need replacing but you will need to check these items with an insulation tester or a mega.  the most common to fail is the heater as these machines do get a lot of moisture around the element.

 I have added some videos below to assist you in any  repairs and also a full exploded diagram of your machine showing you all the components and a full list of parts below that

 

 

 

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

Common Beko Condenser Tumble Dryer DC7112W faults with links to the right repair guide

I have included a lot of videos in the links below on these tumble dryers to assist you in repairing your tumble dryer; I have also included an exploded diagram of your machine with all the parts that you need listed below that just click on the relevant and it will take you to a search result

  1. No heat

This is the most common fault on tumble dryers.

Vented dryers: this can be a fault with the thermostats, heater, or on some occasions, it might be the timer or the relay on the printed circuit board.

Condensor dryers: this might be any of the above but you also have a condenser plate that collects the water and then is either pumped to the collection tray or flows into a tank. Check pump unit and float switches.

Heat pump dryers: these are much more complicated they use a refrigeration prosses to heat the cloths and use the cooling side to condense the water for collection. Check compressor is running, check NTC sensors and check filters, and also that it has the right amount of refrigeration gas (normally only done by an engineer)

  1. Drum not turning

This will stop the dryer from drying. You may have to replace a faulty belt or in other cases, look at the motor, motor capacitor, or the jockey wheels. Again there are relays on printed circuit board types that can go faulty.

  1. Not starting

Whilst, not a common problem, you may have a faulty door switch, starter relay if fitted, or can be start button or PCB.

  1. Noisy Machine

This is usually caused by faulty bearings, jockey wheels or worn felt pads. The motor can get dust build up in the bearings, also the fan blades can distort in shape and make noise rubbing the housing.

  1. Water leaks.

This can be a simple as the water tank (in a condenser tumble dryer) has not been emptied, or not placed back into the housing correctly. The condenser plate can need cleaning. The pump unit might not be working. Or the ducting system can be clogged with fluff etc. See servicing tumble dryer.

  1. Tumble dryer reports a fault code or error code.

Error codes can be on the display or given in certain lights flashing sequences. Tumble dryer fault codes are not universal but may only point you or an engineer in the right direction they are not 100% accurate they are only that for guidance. Your owner’s manual may help you identify the problem and even suggest a fix. In other cases, you’ll need an engineer to trace the fault. Don’t be tempted to ignore a fault code, even if the dryer seems to be functioning normally. Some codes are ‘early warning signs’ and fixing the machine at an early stage could save you time and money in the long run.Contact us with the full model number and detailed description 

If you need any further assistance please feel free to contact me​. all the best Paul​.

photo  
Paul Charmbury
Appliances Engineer
youtube facebook google+ beer

Reference Part Number Description
1 2963930100 TOP PLATE
10 2976900100 FRONT DOOR ASSEMBLY
1003 2971650300 CAPACITOR (ARCOTRONICS 9 uF)
1044 133000001 WASHER 12x18x1 DIN 988..
1045 160200200 ZEEGER 9x1 DIN 6799 DRCS68
1046 2973900600 REAR PANEL ASSY
1087 2963110100 HOSE AND CABLE HOLDER
1098 2962630100 FAN COVER - COOLING
1199 2957880100 SWITCH HOLDER
12 2962120100 INNER DOOR_(ARES_ARC1_WITHOUT_SWITCH)
1205 2707730100 PLASTIC SCREW (DIAMETER 3x6)
1209 2969500300 LOCK BODY ASS
1211 2963910100 LIGHT GUIDE
1230 2961000100 WATER CONDUCTOR ASSY.
1231 2985800100 WATER HOLDER ASSY. (GASKET)
1240 2953510100 O-RING (17,86X2,62)
1241 2953520100 O-RING (9 X 2)
1244 2979290100 POMP COVER
1256 2973100200 SHAFT-FRONT BEARING ASSY
1259 2972300100 FILTRE CASETTE ASSY
1260 2972870100 OVERFLOW FLOAT
1268 2963670200 LIGHT GUIDE SET
1271 2970020100 AIR GUIDING PART
1279 2962560300 BEARING SENSOR COVER
1287 2960150100 RUBBER STOPPER
1290 2962590100 DOOR GASKET
1295 2963120100 MOTOR BRACKET CLAMP (PLASTIC)
1313 2705810300 PT SCREW (3_5x8)
1314 2983560100 COOLING_AIR_EXIT_ROUTER
1377 2965200600 MAIN CABLE ASSEMBLY
1390 9002900200 COUNTERSUNK HEAD SCREW (PT-4X14)
1391 2951610300 DELTA PT SCREW(5x20 TORX HEAD_PERFOR.)
1398 2951780300 DELTA PT VIDA 50x26 WN 5454 HB
1399 2960680100 NTC-THERMOSTAT GASKET
14 2962170200 HINGE
1401 2963210100 MOTOR SHAFT SEAL
1417 2705810400 PT SCREW (3_5x14)
1440 2961690100 ADJUSTABLE PLASTIC FOOT
1451 2963180200 BACK COVER FELT
1453 2953741500 SINGLE ADHESINE EPDM FOAM
1454 2963090200 AIR GUIDING GASKET
1455 2962810100 SIDE WALL PIN
1459 2974680200 WHEEL (RUBBER)
1459 2987300200 WHEEL (RUBBER)
1460 2951261200 POMP WATER TANK HOSE.
1462 2951260800 POMP WATER TANK HOSE.
1466 9003272000 PLASTIC SCREW (DIAMETER 4x10) INOX
1469 100700120 SCREW (B4.2*9.5 DIN 7982-H)
1471 2953741100 SINGLE ADHESINE EPDM FOAM.
1473 2962390100 LOCK MOUTH
1478 2963420100 WATER COLLECTOR
1481 2963950200 COLD AIR ROUTER
1483 2963250100 COOLING AIR OUTFLOW FELT
1484 2963590100 YAN DESTEK (SAG-54CM)
1485 2963610100 SIDE SUPPORT (LEFT)
1486 2974470700 SHAFT DRUM COVER SHC ALS
1486 2974470300 SHAFT DRUM COVER
1486 2974470100 SHAFT DRUM COVER
1489 2962290100 DOWN HINGE GUIDE
1490 2962310100 UP HINGE GUIDE
1497 9003271700 PLASTIC SCREW
1504 2982700100 FLUFF FILTER ASSY.
1517 2953741400 SINGLE ADHESINE EPDM FOAM
1587 2966990100 CABLE TRAY
1588 2967080100 RACEWAY SOCKET GUARD
166 2978270100 MAIN CABLE ASSEMBLY
169 2970445400 POWER SUPPLY CORD
18 2973500100 ADJUSTABLE PLASTIC FOOT ASSY.
180 2964170100 ON_OFF SWITCH(ROLD (+) FORM)
186 2963163001 ELECTRONIC PCB ASSY.(TERRA AV BAZ_PRIME)
189 491500303 POLY-V 285 H 4 MA BELT
200 2975209027 PANEL BODY
2013 2970540100 POWER PLUG HOLDER
203 2976702100 PROGRAMME KNOB BUTTOM_ASSY
2071 2972960100 DUAL SOCKET COVER
2072 2972950100 DUAL SOCKET CASING COVER
208 2963669027 PANEL BODY
300 2963680100 FUUNCTION BUTTON
33 9001230800 PLASTIC CLAMP 152 mm
339 2963640100 OUTER DOOR
341 2962150100 LOCK HOOK
401 2963580100 FRONT PANEL
402 2965080100 FIXER
412 100601820 SCREW (B4.2x16 DIN 7981-H)
4210 2974870100 INTERFERENCE FILTER
43 2960311135 USER'S MANUAL (EU LANGUAGES)
468 2963710100 ON OFF BUTTON (TIP02+ARC 734 MAVI)
48 2985421700 DRUM ASSEMBLY
481 2959000100 SELECTION SWITCH ASSY.
581 2966980100 HEATER CABLE GUARD
583 2705870100 SELF LOCKING CABLE HOLDER
584 2967011100 DRUM LIFTER
59 2962470200 End Of Life ELASTIC POLY-V BELT. 7PH 1956
63 2971420100 Dryer Motor Group WELLING
632 2962160100 HINGE BUSHING
65 2970102000 HEATER ASSY
750 2961850100 PCB HOLDER
804 2973801100 REAR DRUM TIGHTNESS PLATE ASSY
804 2973800700 REAR DRUM TIGHTNESS PLATE ASSY
804 2973800100 REAR DRUM TIGHTNESS PLATE ASSY
822 2963540100 KICK PLATE - LEFT
826 2972900800 HEATER COVER ASSY
826 2972900500 HEATER COVER ASSY
827 2962020100 UPPER BEAM
8303 9003270200 PLASTIC SCREW
8318 2002370900 HOSE CLAMP (Ø 16.4)
8320 100601520 SHEET METAL SCREW (B4.2X13 DIN 7981-H)
834 2959400200 REAR BEARING ASSEMBLY
8384 9003270100 PLASTIC SCREW
8385 9003270400 PLASTIC SCREW (4_10)
8386 9003270500 PLASTIC SCREW (4_12)
8388 2966700200 SUPPORT PART OF SHEET TOP PLATE ASSY.
8392 9003610300 sheet metal screw(B4_2x9_5-perforated)
8394 2705810100 PT SCREW (3_5x9.5)
8397 9003610100 SHEET METAL SCREW(B4_2x9_5-perforated)
8403 9003860300 SHEET METAL SCREW
8413 120800120 FIBERED_NUT_M6X1_DIN_985
8415 2826510200 DOWEL PLASTIC CLAMP
8419 2963340100 End Of Life WASHERED NUT (M6x1)
842 2960190100 CABLE HOLDER
8422 2951580400 COUNTERSUNK HEAD PT SCREW (4.5x12)
8428 2971870100 MX10 RYSB PERFORATED SCREW
843 2964470100 WATER TANK (BOTTOM_7KG_54CM)
8434 2951780400 DELTA PT SCREW
844 2958330200 WATER CAP BOTTOM
845 2963530100 KICK PLATE - RIGHT
846 2962680100 CONDENSER SNAPPER
847 2975700700 PLASTIC CHASIS ASSY
856 2974940100 HINGE PIN HOLDER (PLASTIC)
857 2963150100 SPRING
861 2963330400 FRONT SELING FELT
873 2963230100 PCB HOLDER COVER
877 2971100100 PROCESS FAN ASSY
888 2951060600 MICRO SWITCH
888 2951060700 End Of Life MICRO_SWITCH
888 2951061000 MICRO_SWITCH
891 2961680100 COOLING FAN
9 2963650100 HANDLE
906 2961190200 SPECİAL WASHER (8,1*17*1,5)
921 2980000300 CONDENDER ASSY. (54CM)
921 2980000200 CONDENDER ASSY. (54CM)
925 2953450400 THERMOSTAT ASSEMBLY(L_950MM_78+-3 C)
925 2953450700 THERMOSTAT ASSEMBLY
932 2961961100 SIDE PANEL
985 2954700100 End Of Life Micro Switch Ass.
985 2954700400 Micro Switch Ass.

full list of spare parts for Beko Condenser Tumble Dryer DC7112W

Our How-to-repair stores

Current page 1 Total pages 0

One Response to “Beko Condenser Tumble Dryer DC7112W KEEPS TRIPPING ELECTRIC”

  1. Gavin Kavanagh says : Reply

    Have a beko tumble dryer and just went to use it amd there’s no power to it at all. I’ve cleaned it out very well as usually in filters in all. Also it’s not the power fuse tried reseting it, but still to no use.
    Cam you help please

    Thanks Gavin Kavanagh