Zanussi Condenser Tumble Dryer ZDE47200W Does not heat up
Continuity good on heater element and the two thermostats on the heater assembly. This model is different from the video. No 3rd thermostat in drum. Could it be the circuit card?
Ward Brian
I will try and help with your Zanussi Condenser Tumble Dryer ZDE47200W problem.
If the element and the two thermostats on the element are ok, it can be a problem in the PCB, on a relay most likely or in the logic chip, the one with all the code to make the machine work its functions. If it is the relay you can replace it on the board and it should be ok. If it is the programming chip however you will have to replace the complete board. Check this tutorial for help in diagnosing and testing the relays on the board. If that does not solve it you can check price and availability on the pcb by looking up the number on the schematics provided below.
Please note: there are 3 models for the reference you indicated us "ZDE47200W"
ZDE47200W 91609336601 , ZDE47200W 91609336602 , ZDE47200W 91609336603
For the schematics and parts list below we used model ZDE47200W 91609336601 ,
Make sure you are buying parts with your specific model reference.
If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.
YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page
Common Zanussi Tumble Dryer ZDE47200W faults with links to the right repair guide
I have included a lot of videos in the links below on these tumble dryers to assist you in repairing your tumble dryer; I have also included an exploded diagram of your machine with all the parts that you need listed below that just click on the relevant and it will take you to a search result
- No heat
This is the most common fault on tumble dryers.
Vented dryers: this can be a fault with the thermostats, heater, or on some occasions, it might be the timer or the relay on the printed circuit board.
Condensor dryers: this might be any of the above but you also have a condenser plate that collects the water and then is either pumped to the collection tray or flows into a tank. Check pump unit and float switches.
Heat pump dryers: these are much more complicated they use a refrigeration prosses to heat the cloths and use the cooling side to condense the water for collection. Check compressor is running, check NTC sensors and check filters, and also that it has the right amount of refrigeration gas (normally only done by an engineer)
- Drum not turning
This will stop the dryer from drying. You may have to replace a faulty belt or in other cases, look at the motor, motor capacitor, or the jockey wheels. Again there are relays on printed circuit board types that can go faulty.
- Not starting
Whilst, not a common problem, you may have a faulty door switch, starter relay if fitted, or can be start button or PCB.
- Noisy Machine
This is usually caused by faulty bearings, jockey wheels or worn felt pads. The motor can get dust build up in the bearings, also the fan blades can distort in shape and make noise rubbing the housing.
- Water leaks.
This can be a simple as the water tank (in a condenser tumble dryer) has not been emptied, or not placed back into the housing correctly. The condenser plate can need cleaning. The pump unit might not be working. Or the ducting system can be clogged with fluff etc. See servicing tumble dryer.
- Tumble dryer reports a fault code or error code.
Error codes can be on the display or given in certain lights flashing sequences. Tumble dryer fault codes are not universal but may only point you or an engineer in the right direction they are not 100% accurate they are only that for guidance. Your owner’s manual may help you identify the problem and even suggest a fix. In other cases, you’ll need an engineer to trace the fault. Don’t be tempted to ignore a fault code, even if the dryer seems to be functioning normally. Some codes are ‘early warning signs’ and fixing the machine at an early stage could save you time and money in the long run.Contact us with the full model number and detailed description
-
Replace vented tumble dryer belt Aeg, Electrolux & Zanussi Etc
-
Condenser tumble dryer not heating up Aeg, Electrolux & Zanussi Etc
-
Printed Circuit Board Repairs for Tumble dryers AEG, Electrolux, Zanussi Etc
-
E21, E22 Error Code, Tumble Dryer Pump Fault AEG, Electrolux, Zanussi Etc
-
Tumble Dryer fault code errors Aeg, Electrolux, Zanussi Etc
-
How to replace a belt on a condenser tumble dryer Zanussi, Electrolux & Aeg
Match your part for Zanussi Tumble Dryer ZDE47200W and use reference number in list below and click on the link to your part
Reference | Part Number | Description |
---|---|---|
110 | 1250220108 | DRYER VENT HOSE - 3M |
130A | 1250978101 | GASKET,DUCT |
135 | 1257922300 | CHANNEL DRAINAGE,AIR,WITHOUT,L |
260A | 1250202007 | SPRING,SIDE PANEL |
303 | 1254271206 | |
309 | 1254003021 | BEZEL,REAR PANEL,NEX4 |
313 | 1361004003 | WORK TOP,ENV06 VENT. |
322 | 1250093067 | CROSSBAR,UPPER |
324 | 1364004505 | FRONT PANEL,WHITE,ENV06 VENTED |
326 | 1364007706 | SIDE PANEL,LEFT,TDV NX1-4 |
326 | 1364007805 | SIDE PANEL,RIGHT,TDV NX1-4 |
330 | 1256640002 | ADJUSTABLE FOOT |
334 | 1254265174 | REAR PANEL,NEXUS4 |
521 | 1254262007 | HOLE COVER,FRONT PANEL,NEX4 |
521A | 1250090006 | DRAIN PLUG |
523 | 1254160011 | BRACKET,HARNESS,NEX/4 TDC |
523A | 1257921104 | FILTER WITH POCKET |
523C | 1257935005 | FAN PROTECTION |
527 | 1250091004 | RING NUT VENT |
550A | 1254304056 | COAT,BACK PANEL,NX1 |
555 | 1254261009 | DECOR PLATE,HINGE,NEX4 |
999 | 1369161003 | USER MANUAL,EN |
Reference | Part Number | Description |
---|---|---|
004 | 1251209035 | MOTOR,SHIELD,PLATE,2P SOLE |
007 | 1254253154 | DOOR LOCK,EMZ NX4 |
010 | 1257533263 | HEATING ELEMENT,240V,1400+600W |
011 | 1250020334 | INTERFERENCE CAPACITOR,8UF |
037 | 1254227042 | ASSEMBLY,TERMINAL BLOCK,NEX4 I |
048C | 1242940102 | TEMPERATURE PROBE,NTC |
130C | 1246644007 | GASKET,PROBE |
159 | 1250019112 | FAN WHEEL |
260A | 1258474012 | TENSION SPRING,MOTOR |
263 | 1250125208 | CLAMPING ROLLER,ASSEMBLY |
523 | 1250362009 | ASSEMBLY,MOTOR HOLDER,FRONT |
523A | 1254035114 | ASSEMBLY,MOTOR SUPPORT |
587 | 1257580405 | NOT CONFIGURED ELECTRONIC,ENV0 |
587 | 973916093366011 | CONFIGURED ELECTRONIC,ENV06,LE |
999 | 3705244014 | POWER CABLE,3 X 1 X 1600 - UK- |
999 | 3705366023 | HARNESS,COMPLETE |
999 | 50681033002 | DISC |
Reference | Part Number | Description |
---|---|---|
130 | 1255025601 | GASKET,FRONT,BASKET,NEX4 |
130A | 1250129200 | GASKET,BACK,BASKET |
250 | 1256910900 | ASSEMBLY,DRUM,(EM.ZZZ)SMART A |
253 | 1258288107 | BELT,L=1975 |
255A | 1250134119 | BEARING FLANGE |
262 | 1256923119 | DRUM LIFTER,3 PCS. |
335 | 1364059004 | ASSEMBLY,ROLL,CHANNEL DRAINAGE |
520A | 1250232053 | AXLE COMPLETE |
531 | 1240222123 | SCREW,MOTOR |
550 | 1255061077 | COAT,BOLT,BASKET |
999 | 1051185005 | DISC,13X18 |
Reference | Part Number | Description |
---|---|---|
500 | 1260690100 | KNOB,PROGRAMMES,SMART |
510 | 1368047112 | CONTROL PANEL,SILKSCREENED |
525 | 1257968006 | PUSH BUTTON,START,PAUSE |
525A | 1257969202 | BUTTONS,FUNCTION,ENV06 VENT. T |
525C | 1361005000 | BUTTON SUPPORT,BUTTON SPRINGIN |
535 | 1257966604 | DIFFUSER,ENV06 VENT. TC6 |
563 | 1257385003 | SHAFT,SELECTOR |
999 | 1363013002 | SPACE COMPENSATOR,KNOB,Ø 6,2-1 |
Reference | Part Number | Description |
---|---|---|
013 | 1254302001 | DOOR OPENING BUTTON,NEX4 |
130 | 1254251000 | GASKET,DOOR,NEX4 |
260A | 1254303017 | SPRING,EJECTOR,DOOR CATCH,NEX4 |
308 | 1254454018 | DOOR HINGE |
308A | 1257523009 | STIFFENING,DOOR HINGE,PLASTIC, |
323 | 1257920312 | INNER DOOR,ENV06 AEG VENT. |
323A | 1254244112 | DECOR FRAME,OUTER DOOR,NX4 |
325 | 1254263203 | DOOR CATCH,WHITE |
555B | 1254252016 | COVER |
563 | 1254248006 | PIVOT,DOOR HINGE,NEX4 |