Continuity good on heater element and the two thermostats on the heater assembly. This model is different from the video. No 3rd thermostat in drum. Could it be the circuit card?

Ward Brian

Paul answers

I will try and help with your Zanussi Condenser Tumble Dryer ZDE47200W problem.

If the element and the two thermostats on the element are ok, it can be a problem in the PCB, on a relay most likely or in the logic chip, the one with all the code to make the machine work its functions. If it is the relay you can replace it on the board and it should be ok. If it is the programming chip however you will have to replace the complete board. Check this tutorial for help in diagnosing and testing the relays on the board. If that does not solve it you can check price and availability on the pcb by looking up the number on the schematics provided below.

 

Please note: there are 3 models for the reference you indicated us "ZDE47200W"

ZDE47200W 91609336601 , ZDE47200W 91609336602 , ZDE47200W 91609336603

For the schematics and parts list below we used model ZDE47200W 91609336601 , 
Make sure you are buying parts with your specific model reference.

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

Common Zanussi Tumble Dryer ZDE47200W faults with links to the right repair guide

I have included a lot of videos in the links below on these tumble dryers to assist you in repairing your tumble dryer; I have also included an exploded diagram of your machine with all the parts that you need listed below that just click on the relevant and it will take you to a search result

  1. No heat

This is the most common fault on tumble dryers.

Vented dryers: this can be a fault with the thermostats, heater, or on some occasions, it might be the timer or the relay on the printed circuit board.

Condensor dryers: this might be any of the above but you also have a condenser plate that collects the water and then is either pumped to the collection tray or flows into a tank. Check pump unit and float switches.

Heat pump dryers: these are much more complicated they use a refrigeration prosses to heat the cloths and use the cooling side to condense the water for collection. Check compressor is running, check NTC sensors and check filters, and also that it has the right amount of refrigeration gas (normally only done by an engineer)

  1. Drum not turning

This will stop the dryer from drying. You may have to replace a faulty belt or in other cases, look at the motor, motor capacitor, or the jockey wheels. Again there are relays on printed circuit board types that can go faulty.

  1. Not starting

Whilst, not a common problem, you may have a faulty door switch, starter relay if fitted, or can be start button or PCB.

  1. Noisy Machine

This is usually caused by faulty bearings, jockey wheels or worn felt pads. The motor can get dust build up in the bearings, also the fan blades can distort in shape and make noise rubbing the housing.

  1. Water leaks.

This can be a simple as the water tank (in a condenser tumble dryer) has not been emptied, or not placed back into the housing correctly. The condenser plate can need cleaning. The pump unit might not be working. Or the ducting system can be clogged with fluff etc. See servicing tumble dryer.

  1. Tumble dryer reports a fault code or error code.

Error codes can be on the display or given in certain lights flashing sequences. Tumble dryer fault codes are not universal but may only point you or an engineer in the right direction they are not 100% accurate they are only that for guidance. Your owner’s manual may help you identify the problem and even suggest a fix. In other cases, you’ll need an engineer to trace the fault. Don’t be tempted to ignore a fault code, even if the dryer seems to be functioning normally. Some codes are ‘early warning signs’ and fixing the machine at an early stage could save you time and money in the long run.Contact us with the full model number and detailed description 

If you need any further assistance please feel free to contact me​. all the best Paul​.

photo  
Paul Charmbury
Appliances Engineer
youtube facebook google+ beer

Match your part for Zanussi Tumble Dryer ZDE47200W and use reference number in list below and click on the link to your part

Reference Part Number Description
110 1250220108 DRYER VENT HOSE - 3M
130A 1250978101 GASKET,DUCT
135 1257922300 CHANNEL DRAINAGE,AIR,WITHOUT,L
260A 1250202007 SPRING,SIDE PANEL
303 1254271206
309 1254003021 BEZEL,REAR PANEL,NEX4
313 1361004003 WORK TOP,ENV06 VENT.
322 1250093067 CROSSBAR,UPPER
324 1364004505 FRONT PANEL,WHITE,ENV06 VENTED
326 1364007706 SIDE PANEL,LEFT,TDV NX1-4
326 1364007805 SIDE PANEL,RIGHT,TDV NX1-4
330 1256640002 ADJUSTABLE FOOT
334 1254265174 REAR PANEL,NEXUS4
521 1254262007 HOLE COVER,FRONT PANEL,NEX4
521A 1250090006 DRAIN PLUG
523 1254160011 BRACKET,HARNESS,NEX/4 TDC
523A 1257921104 FILTER WITH POCKET
523C 1257935005 FAN PROTECTION
527 1250091004 RING NUT VENT
550A 1254304056 COAT,BACK PANEL,NX1
555 1254261009 DECOR PLATE,HINGE,NEX4
999 1369161003 USER MANUAL,EN

Reference Part Number Description
004 1251209035 MOTOR,SHIELD,PLATE,2P SOLE
007 1254253154 DOOR LOCK,EMZ NX4
010 1257533263 HEATING ELEMENT,240V,1400+600W
011 1250020334 INTERFERENCE CAPACITOR,8UF
037 1254227042 ASSEMBLY,TERMINAL BLOCK,NEX4 I
048C 1242940102 TEMPERATURE PROBE,NTC
130C 1246644007 GASKET,PROBE
159 1250019112 FAN WHEEL
260A 1258474012 TENSION SPRING,MOTOR
263 1250125208 CLAMPING ROLLER,ASSEMBLY
523 1250362009 ASSEMBLY,MOTOR HOLDER,FRONT
523A 1254035114 ASSEMBLY,MOTOR SUPPORT
587 1257580405 NOT CONFIGURED ELECTRONIC,ENV0
587 973916093366011 CONFIGURED ELECTRONIC,ENV06,LE
999 3705244014 POWER CABLE,3 X 1 X 1600 - UK-
999 3705366023 HARNESS,COMPLETE
999 50681033002 DISC

Reference Part Number Description
130 1255025601 GASKET,FRONT,BASKET,NEX4
130A 1250129200 GASKET,BACK,BASKET
250 1256910900 ASSEMBLY,DRUM,(EM.ZZZ)SMART A
253 1258288107 BELT,L=1975
255A 1250134119 BEARING FLANGE
262 1256923119 DRUM LIFTER,3 PCS.
335 1364059004 ASSEMBLY,ROLL,CHANNEL DRAINAGE
520A 1250232053 AXLE COMPLETE
531 1240222123 SCREW,MOTOR
550 1255061077 COAT,BOLT,BASKET
999 1051185005 DISC,13X18

Reference Part Number Description
500 1260690100 KNOB,PROGRAMMES,SMART
510 1368047112 CONTROL PANEL,SILKSCREENED
525 1257968006 PUSH BUTTON,START,PAUSE
525A 1257969202 BUTTONS,FUNCTION,ENV06 VENT. T
525C 1361005000 BUTTON SUPPORT,BUTTON SPRINGIN
535 1257966604 DIFFUSER,ENV06 VENT. TC6
563 1257385003 SHAFT,SELECTOR
999 1363013002 SPACE COMPENSATOR,KNOB,Ø 6,2-1

Reference Part Number Description
013 1254302001 DOOR OPENING BUTTON,NEX4
130 1254251000 GASKET,DOOR,NEX4
260A 1254303017 SPRING,EJECTOR,DOOR CATCH,NEX4
308 1254454018 DOOR HINGE
308A 1257523009 STIFFENING,DOOR HINGE,PLASTIC,
323 1257920312 INNER DOOR,ENV06 AEG VENT.
323A 1254244112 DECOR FRAME,OUTER DOOR,NX4
325 1254263203 DOOR CATCH,WHITE
555B 1254252016 COVER
563 1254248006 PIVOT,DOOR HINGE,NEX4

full list of spare parts for Zanussi Tumble Dryer ZDE47200W

Our How-to-repair stores

Current page 1 Total pages 0
  • Tumble Dryer Temperature Sensor NTC Probe : K276 3792171203 1242940102

    Category: Recycle Appliances

    £8.30
  • Tumble Dryer Drum Roller Wheel Support Bearing 1364059004

    Category: Recycle Appliances

    £8.90
  • Tumble Dryer Belt 1975 7 Rib 1258288107

    Category: Recycle Appliances